WEBVTT

00:00.400 --> 00:03.480
Hello everyone, this is Sebastian, I'm Thomas from

00:03.480 --> 00:04.300
Lichtvision Engineering.

00:04.660 --> 00:06.180
We're here to give you a little update

00:06.180 --> 00:07.800
on our ProbitSite.

00:08.420 --> 00:11.580
We just launched our firmware release 1.5

00:11.580 --> 00:13.660
and would like to inform you on a

00:13.660 --> 00:15.100
couple of new things.

00:15.440 --> 00:18.600
In short, as a summary, we launched the

00:18.600 --> 00:19.360
expert mode.

00:19.640 --> 00:23.880
It's a mode that allows customers to change

00:23.880 --> 00:26.600
something in the configuration once it's set into

00:26.600 --> 00:28.520
this expert mode.

00:29.000 --> 00:30.080
And the other thing we would like to

00:30.080 --> 00:32.100
inform you about is a feature that has

00:32.100 --> 00:34.200
been there from the beginning but is not

00:34.200 --> 00:37.040
known to many of you, which is the

00:37.040 --> 00:38.200
data logging function.

00:38.520 --> 00:40.960
But the details will be explained by Sebastian.

00:41.880 --> 00:44.940
So let's start by powering up the device.

00:46.100 --> 00:49.500
With the new firmware you have the expert mode

00:49.500 --> 00:53.680
that you can enable inside the

00:53.680 --> 00:54.800
Probit Site App.

00:54.960 --> 00:56.820
The difference is you can see there's a

00:56.820 --> 00:59.260
small special icon on the bottom right that

00:59.260 --> 01:00.800
indicates you are in the expert mode.

01:01.500 --> 01:04.900
Normally when you get the device, it starts

01:04.900 --> 01:07.440
in the normal mode, like you can see

01:07.440 --> 01:07.720
here.

01:07.980 --> 01:10.520
There's a different boot screen and there's no

01:10.520 --> 01:13.280
special icon on the bottom right side.

01:14.240 --> 01:16.100
How to change into the expert mode

01:16.100 --> 01:16.760
I will show you later.

01:17.500 --> 01:21.960
For this example, I made a small configuration.

01:22.300 --> 01:25.560
I have three devices that I'm going to

01:25.560 --> 01:28.080
connect to the ProbitSite and we got

01:28.080 --> 01:30.120
some problems here that I'm going to show

01:30.120 --> 01:30.740
you just now.

01:31.560 --> 01:34.100
First, let's start a scan.

01:39.000 --> 01:41.800
You can see that there are already some problems.

01:42.080 --> 01:44.740
We have one addressed device and one unaddressed

01:44.740 --> 01:45.160
device.

01:45.960 --> 01:48.000
In this example, let's say you have an

01:48.000 --> 01:50.480
installation with two devices and you put another

01:50.480 --> 01:52.420
one additionally.

01:53.200 --> 01:56.840
In this case, it already has a short address.

01:57.240 --> 01:59.240
You can see we have a possible address conflict.

02:00.180 --> 02:04.220
It detected a device with short address zero

02:04.220 --> 02:05.300
with a possible conflict.

02:06.180 --> 02:08.639
There's a high possibility that there are two

02:08.639 --> 02:10.039
devices with the same address.

02:11.100 --> 02:13.940
We have one device that has no short address.

02:14.780 --> 02:17.800
If you go into this address conflict device,

02:18.020 --> 02:19.460
you can go into device options.

02:20.320 --> 02:21.920
We can identify the device.

02:22.160 --> 02:24.620
It's going to blink and we can also

02:24.620 --> 02:25.360
set an address.

02:26.000 --> 02:28.480
Because we have an address conflict, we can only

02:28.480 --> 02:29.980
delete this short address.

02:31.280 --> 02:34.020
All devices that have the short address zero

02:34.020 --> 02:36.940
are not going to have any address.

02:37.700 --> 02:40.040
You see, I just had a warning and

02:40.040 --> 02:44.420
if I confirm, it should remove the short

02:44.420 --> 02:46.700
address zero from all devices that have this address.

02:47.200 --> 02:49.620
You can also set an address.

02:50.180 --> 02:53.300
For this device, it doesn't have any address.

02:53.740 --> 02:55.940
Maybe you wanted to have one, so you

02:55.940 --> 02:56.700
go into the options.

02:57.100 --> 02:59.800
You can go into set address and you

02:59.800 --> 03:02.560
can give it any address that is not

03:02.560 --> 03:03.020
occupied.

03:03.660 --> 03:05.560
Let's say we give it the address number two.

03:06.520 --> 03:08.700
You see the warning screen again.

03:09.160 --> 03:12.480
You need to confirm and after a short

03:12.480 --> 03:14.840
time, it should have the address number two.

03:16.440 --> 03:20.120
After we resolved this problem with the same

03:20.120 --> 03:23.540
short addresses, you can do another scan.

03:23.940 --> 03:26.880
So you can detect what kind of devices you

03:26.880 --> 03:27.340
have here.

03:27.940 --> 03:30.320
You can read all the information about them.

03:31.840 --> 03:35.440
You see, we have one addressed device and

03:35.440 --> 03:37.280
two unaddressed devices.

03:40.320 --> 03:44.580
Because we resolved this conflict, we can see

03:44.580 --> 03:46.740
the information about these devices.

03:47.440 --> 03:50.980
We have the device number two that we

03:50.980 --> 03:53.700
gave this address to and we have two

03:53.700 --> 03:56.040
devices that do not have an address.

03:56.700 --> 03:59.300
Those are the devices that had this conflict.

04:01.160 --> 04:04.340
Like Thomas already said, the time you turn

04:04.340 --> 04:06.520
on the device, it's going to start recording

04:06.520 --> 04:08.340
everything that happens on the DALI bus.

04:09.020 --> 04:11.360
The time you power it off,

04:11.360 --> 04:13.120
it's going to save this log.

04:13.440 --> 04:16.400
We call it DALI log, sometimes sniffer.

04:17.900 --> 04:20.920
If I connect it to my computer,

04:20.920 --> 04:21.800
like so.

04:24.390 --> 04:27.270
As you can see on my screen,

04:27.270 --> 04:30.730
if I click on the connect button, it is

04:30.730 --> 04:32.110
going to connect to this device.

04:32.850 --> 04:35.230
If it's powered off, it's going to power

04:35.230 --> 04:35.790
on again.

04:37.350 --> 04:39.010
You can see it's booting.

04:40.230 --> 04:42.130
It is downloading the scans.

04:42.550 --> 04:44.730
The first scan with the conflicts and the

04:44.730 --> 04:47.110
second scan after we've resolved everything.

04:49.320 --> 04:51.460
It's also importing the log data for them

04:51.460 --> 04:53.980
and now it's importing the full log data.

04:54.200 --> 04:56.320
The data from the time the device was

04:56.320 --> 04:58.340
powered on until it was powered off again.

04:59.720 --> 05:02.940
That means we can put this ProbitSite

05:02.940 --> 05:06.740
into an electrical cabinet or into the false

05:06.740 --> 05:08.040
ceiling to have it recorded.

05:08.660 --> 05:11.380
If you wait for some ghost telegrams or

05:11.380 --> 05:13.260
whatever you have, you can use this as

05:13.260 --> 05:13.840
a data logger.

05:13.900 --> 05:14.140
Exactly.

05:14.660 --> 05:16.940
For example, if you have a problem like

05:16.940 --> 05:19.460
there are some lights that are turning off

05:19.460 --> 05:22.520
every half an hour, you can connect the

05:22.520 --> 05:24.140
ProbitSite to this installation.

05:24.940 --> 05:26.640
If you want to record for more than

05:26.640 --> 05:30.200
one day, I would recommend to plug in

05:30.200 --> 05:33.260
a power supply so the battery doesn't get

05:33.260 --> 05:33.560
empty.

05:34.400 --> 05:38.500
Then you can record for a really long time.

05:39.220 --> 05:41.140
And later on you can see on the

05:41.140 --> 05:44.820
computer what kind of telegrams were sent on

05:44.820 --> 05:48.740
this DALI line and maybe figure out what's

05:48.740 --> 05:49.860
the problem with your installation.

05:52.580 --> 05:54.580
If you want to change into the expert

05:54.580 --> 05:58.680
mode, you need to extend this window on

05:58.680 --> 05:59.180
the left side.

05:59.780 --> 06:02.480
You see all the information about this device.

06:03.240 --> 06:05.460
You see it is already in the expert

06:05.460 --> 06:05.760
mode.

06:05.980 --> 06:07.980
You can change it back to normal mode.

06:08.760 --> 06:10.840
The device is going to turn off and

06:10.840 --> 06:13.960
on again and it is not in the

06:13.960 --> 06:14.820
expert mode anymore.

06:16.400 --> 06:17.880
If you want to go back to expert

06:17.880 --> 06:21.260
mode, you click this button again and you

06:21.260 --> 06:23.980
see you are back to expert mode.

06:24.560 --> 06:26.240
I think this comes in handy if you

06:26.240 --> 06:28.880
want to give this device to a less

06:28.880 --> 06:31.640
trained person to do some testing and you

06:31.640 --> 06:35.040
don't want to endanger the installation with faults

06:35.040 --> 06:35.600
being made.

06:35.980 --> 06:38.120
But if you yourself are the expert, you

06:38.120 --> 06:39.820
activate the expert mode and you can change

06:39.820 --> 06:40.360
things.

06:40.500 --> 06:43.960
That's how we thought we basically allow for

06:43.960 --> 06:46.100
changes at the same time, keep our promise

06:46.100 --> 06:50.960
that we prevent installations from being corrupted by

06:50.960 --> 06:52.540
misuse.

06:52.920 --> 06:53.160
Exactly.

06:55.100 --> 06:58.820
Like I said before, it imports the log data.

06:58.830 --> 07:02.560
All the imported data goes into this imported

07:02.560 --> 07:03.140
directory.

07:04.520 --> 07:06.120
You can see we have the two scans.

07:06.280 --> 07:07.940
The first scan with the conflicts, the second

07:07.940 --> 07:10.700
scan without the conflicts, the other way around.

07:11.000 --> 07:12.940
This is with the conflicts, this is without

07:12.940 --> 07:13.420
the conflicts.

07:14.100 --> 07:17.300
You can go inside and we see all

07:17.300 --> 07:18.480
the devices that we have detected.

07:19.980 --> 07:22.740
The special feature that was already there but

07:22.740 --> 07:25.260
not many people knew about is the logging

07:25.260 --> 07:25.660
feature.

07:26.060 --> 07:27.140
It's on this tab, logs.

07:27.720 --> 07:31.520
You can see the scan we just did.

07:31.800 --> 07:33.880
We can see the time we just had,

07:34.400 --> 07:38.200
10:53, and you can open the log

07:38.200 --> 07:41.340
data for this power cycle.

07:43.000 --> 07:45.120
On the left side, you can see everything

07:45.120 --> 07:46.320
that happened with the device.

07:46.600 --> 07:49.460
It was powered up, we started the scan,

07:50.100 --> 07:54.200
there were some address changes and another scan.

07:54.800 --> 07:56.820
Exactly what we just did today.

07:57.700 --> 07:59.920
On the right side, you can see everything

07:59.920 --> 08:01.120
that happened on the DALI line.

08:02.420 --> 08:04.440
If we would not do any scan and

08:04.440 --> 08:07.600
there would be some installation that's already in

08:07.600 --> 08:09.840
use, you would see all the telegrams on

08:09.840 --> 08:10.320
the right side.

08:10.640 --> 08:13.140
If I expect some behavior, can I also

08:13.140 --> 08:14.240
search in the log?

08:14.420 --> 08:16.320
Yes, in the top, you can see this

08:16.320 --> 08:17.540
search button.

08:18.500 --> 08:24.960
You can search, for example, for address number

08:24.960 --> 08:25.980
one.

08:26.620 --> 08:27.340
I hope there is one.

08:28.020 --> 08:29.540
Yes, there is one.

08:29.980 --> 08:33.780
You can see there's something that is happening

08:33.780 --> 08:36.800
with the device number, with the short address one.

08:37.419 --> 08:39.860
If you see this icon, it means this

08:39.860 --> 08:41.659
is something that we have sent, that ProbitSite

08:41.659 --> 08:43.660
has sent, if there's an arrow up,

08:43.860 --> 08:45.520
that means we have sent it.

08:50.220 --> 08:52.080
I think I didn't forget anything.

08:52.380 --> 08:52.980
No, good.

08:53.240 --> 08:53.520
Thank you.

08:53.560 --> 08:54.960
Thank you so much for the update, Sebastian,

08:55.380 --> 08:56.740
and have fun with our product.