ProbitLab2 – Downloads & FAQs

Downloads


ProbitLab2 V4.14.zip (2024-02-23)

Description

  • ProbitLab2 firmware
  • It is recommended to use the latest Probit driver

New changes

  • For ProbitBench V4.5.0.0 and higher
  • Added support for multiple frame detect with bit frame transmission trigger
  • Internal optimizations
Previous changes

Changes related to ProbitLab2 V4.13:
· For ProbitBench V4.3.3.0 and higher
· Internal optimizations

Changes related to ProbitLab2 V4.12:
· For ProbitBench V4.3.0.0 and higher
· Revised communication protocol for future needs

Changes related to ProbitLab2 V4.11:
· For ProbitBench V4.2.8.0
· Revised communication protocol for future needs
· Bugfix usage of internal I2C bus

Changes related to ProbitLab2 V4.10:
· For ProbitBench V4.2.5.0, V4.2.6.0 and V4.2.7.0
· Revised communication protocol for future needs
· Note: This update allows higher accuracy of analog voltage measurement of the DALI input and the DALI input receiver thresholds. To make use of it, please calibrate with the Probit Calibrator Tool V4.3 (see below).

Changes related to ProbitLab2 V4.9:
· For ProbitBench V4.2.1.0, V4.2.2.0 and V4.2.3.0
· Optimization of firmware to run 3xx test sequences
· Optimization of transmission timings

Changes related to ProbitLab2 V4.8:
· For ProbitBench V4.2.0.0
· Revised communication protocol for future needs
· Bus receiving optimized
· Bugfix transmission timing issue

Changes related to ProbitLab2 V4.7:
· For ProbitBench V4.2.0.0
· Revised communication protocol for future needs
· Relay switching behaviour optimized
· Receive / Transmit LED blinking behaviour optimized
· Bus receiving optimized to allow faster transmissions by ProbitBench
· Bugfix 15 bit frame transmission issue
· Bugfix resync issue

Changes related to ProbitLab2 V4.6:
· For ProbitBench V4.1.0.0 and V4.1.1.0
· Revised communication protocol for 103 and future needs

Changes related to ProbitLab2 V4.5:
· For ProbitBench V4.0.0.4 and V4.0.0.5
· Revised communication protocol for future needs

Changes related to ProbitLab2 V4.4:
· For ProbitBench V4.0.0.3
· Bugfix regarding frame transmission handling

Changes related to ProbitLab2 V4.3:
· For ProbitBench V4.0.0.2
· Bugfix regarding sporadic communication errors

Changes related to ProbitLab2 V4.2:
· For ProbitBench V4.0.0.2
· Revised communication protocol for future needs

Changes related to ProbitLab2 V4.1:
· For ProbitBench V4.0.0.1
· Bugfix regarding transmission of a frame sequence

Changes related to ProbitLab2 V4.0:
· For ProbitBench V4.0.0.1
· Introduction firmware version


Probit Calibrator Tool V4.3.zip (2019-11-16)

Description

  • Calibration tool for ProbitLab2
  • For ProbitLab V4.10 and higher
  • To calibrate the analog voltage measurement of the DALI input and the DALI input receiver thresholds.
  • Note: Please follow the instructions of the tool very closely.
    It is recommended to calibrate the ProbitLab2 device after upgrading to 4.10 only once.
    Please make sure the ProbitLab2 device is warmed up before calibration.
    We recommend to let operate the device under normal conditions for ca. 1 hour before.

Probit Driver Package 2.12.36.4 WHQL.zip (2021-08-30)

Description

  • Probit hardware driver
  • WHQL certified
  • Note: Previous non-WHQL drivers have no signature so that on some Windows OS versions (e.g. 64-bit versions) you need to install them in a special mode. Follow these instructions.

New changes

  • WHQL certified
  • ProbitDongle device added
Previous changes

Changes related to Probit driver 2.12.28:
· Driver optimizations
· ProbitSite device added

Changes related to Probit driver 2.12.06:
· Driver optimizations
· ProbitLab2 device added

Changes related to Probit driver 2.08.24:
· Driver optimizations
· preliminary Windows 8 driver installation added

Changes related to Probit driver 2.08.02:
· Windows 7 compatibility added


ProbitLab2 – Getting Started.pdf (2017-05-10)

Description

How to get started with ProbitLab2


ProbitLab2 – Example.pdf (2017-05-10)

Description

Example of DUT connection to ProbitLab2


FAQs

Why the ProbitLab2 is not running?

Answer: Please make sure the main supply is connected correctly to the ProbitLab2 and the main supply switch at the back side is on.
Answer: Please make sure the emergency button is not pressed.

Why I cannot measure a voltage at the DALI terminals?

Answer: After power up of the ProbitLab2 the DALI terminals are disabled. After connecting with the ProbitBench software you are able to activate the integrated DALI bus power supply.

Lichtvision Engineering GmbH

Contact infos

address-icon
Address

Fritschestrasse 27/28
10585 Berlin, Germany

phone-icon
Phone

T +49 30 21 28 91 - 0
F +49 30 21 28 91 - 21

email-icon
Email

contact@lichtvision-engineering.com


LICHTVISION

© 2025 Lichtvision Engineering GmbH - All rights reserved

Imprint | Cookie Policy | Declaration of data protection | Privacy Statement